Hach-lange DR 5000 brewerie analysis, supplementary software User Manual

Browse online or download User Manual for Equipment Hach-lange DR 5000 brewerie analysis, supplementary software . Hach-Lange DR 5000 brewerie analysis, supplementary software LZV570 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 52
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
DOC022.52.00730.APR06
Supplementary Software
LZV 570
Brewery Analysis
DR 5000
USER MANUAL
April 2006, Edition 2
© Hach Lange GmbH, 2006. All rights reserved. Printed in Germany.
CK/SK
Page view 0
1 2 3 4 5 6 ... 51 52

Summary of Contents

Page 1 - Brewery Analysis

DOC022.52.00730.APR06Supplementary SoftwareLZV 570Brewery AnalysisDR 5000USER MANUALApril 2006, Edition 2© Hach Lange GmbH, 2006. All rights reserved.

Page 2

10Working proceduresResultsBitter units (BU) without any decimal placesAccuracyr = -0.36 + 0.05 mR = 0.72 + 0.14 mStandard valuesBeer: 10–40 BU, depen

Page 3 - Table of Contents

11Working procedures2.1.2 Procedure for measuring bitter units in wort1. Prepare samples as described in the working procedure.2. Select STORED PROGRA

Page 4

12Working procedures2.2 Total polyphenols (EBC method)PrinciplePolyphenols react with iron(III) ions in an alkaline solution to form coloured iron com

Page 5 - Section 1 General Information

13Working procedures8. Blank value a. Introduce 10 ml sample (expel carbon dioxide from beer by shaking; clarify turbid wort or beer by centrifuging)

Page 6 - General Information

14Working procedures2.2.1.1 Executing the test with the sipper moduleInformation about the installation, module configurations and sample introduction

Page 7 - 1.6 List of abbreviations

15Working procedures2.3 Reducing power (spectrophotometric method)Reducing power is a measure of the rapidly reducing substances present in beer. Redu

Page 8 - 1.7 Literature

16Working procedures2. After the carbon dioxide has been expelled, pipette 10 ml beer into a test tube with a glass stopper, then tilt the tube slight

Page 9 - Section 2 Working procedures

17Working proceduresNote: Analysis of additional samples: Repeat working procedure from point 3. In other words, each sample has to have its own speci

Page 10 - Working procedures

18Working proceduresReagents• MN polyamide SC 6• Solution 1: n-butanol/37% hydrochloric acid 5+1 (V/V).• Solution 2: Dissolve 120 mg iron(II) sulphate

Page 11

19Working procedures2.4.1 Procedure for measuring anthocyanogens1. Prepare samples as described in the working procedure.2. Select STORED PROGRAMS in

Page 13

20Working procedures2.5 Beer colour (spectrophotometric EBC method)PrincipleThis method is designed to eliminate subjective effects attributable to th

Page 14

21Working procedures2.5.1 Procedure for measuring beer colour1. Prepare samples as described in the working procedure.2. Select STORED PROGRAMS in the

Page 15

22Working procedures2.6 Free amino nitrogen (ninhydrin method based on EBC method)PrincipleThe test solution is heated with ninhydrin at pH 6.7 and th

Page 16

23Working procedures5. Loosely close test tube with glass stopper to prevent evaporation losses.6. Heat for exactly 16 min in boiling water in a water

Page 17

24Working procedures2.6.1 Procedure for measuring free amino nitrogen (FAN) in light worts1. Prepare three blank value solutions, three standard solut

Page 18

25Working procedures2.6.2 Procedure for measuring free amino nitrogen (FAN) in light beer1. Prepare three blank value solutions, three standard soluti

Page 19

26Working procedures2.6.3 Procedure for measuring free amino nitrogen (FAN) in dark worts1. Prepare three blank value solutions, three standard soluti

Page 20

27Working procedures2.6.3.1 Executing the test with the sipper moduleInformation about the installation, module configurations and sample introduction

Page 21

28Working procedures8. The FAN result is displayed in mg/l.Note: Analysis of additional samples: Repeat working procedure from point 7. 2.6.4.1 Execut

Page 22

29Working procedures2.7 Steam-volatile phenolsThe degree of fumigation of whisky malts is determined by analysing steam-volatile phenols. In the beer

Page 23

3Table of ContentsSection 1 General Information ...51.1 S

Page 24

30Working procedures• Potassium hexacyanoferrate(III), K3[Fe(CN)6], 8%: prepare freshly each day• Phenol standard solution:Dissolve 1.000 g phenol in

Page 25

31Working proceduresm. Measure the chloroform extract (prepared distillate) in a 40 mm rectangular cuvette at 460 nm against a blank value solution ob

Page 26

32Working proceduresNote: Analysis of additional samples: Repeat working procedure from point 4.2.7.1.1 Executing the test with the sipper moduleInfor

Page 27

33Working procedures• Iodine solution, 0.02N (prepare freshly each day from the stock solution)• Phosphate buffer solution, 0.1M, pH 3.5: adjust the p

Page 28

34Working procedures2.8.1 Procedure for measuring photometric iodine sample1. Prepare samples and iodine blank solution as described in the working pr

Page 29 - 2.7 Steam-volatile phenols

35Working procedures2.9 Thiobarbituric acid number (TAN)The thiobarbituric acid number is a sum parameter for the thermal effects on malt and wort. It

Page 30

36Working procedures4. Main valuea. Add 5 ml thiobarbituric acid to 10 ml diluted sample and shake.b. Place in a 70 °C water bath for 70 minutes (avoi

Page 31

37Working proceduresNote: Analysis of additional samples: Repeat working procedure from point 4.2.9.1.1 Executing the test with the sipper moduleInfor

Page 32

38Working procedures2.9.2.1 Executing the test with the sipper moduleInformation about the installation, module configurations and sample introduction

Page 33

39Working procedures2.10 Iso-α-acids and α-acidsPrincipleThe bitter substances are extracted from the acidified sample with iso-octane. Certain substa

Page 34

4Table of Contents2.11.1 Procedure for measuring vicinal diketones ...442.11.1.1 Exe

Page 35

40Working procedures6. Separate the phases and break the emulsion by centrifuging for 5 min at 3000 rpm.7. Use a pipette to draw off and discard the b

Page 36

41Working procedures2.10.1 Procedure for measuring iso-α-acids and α-acids 1. Prepare samples and blank value solution as described in the working pro

Page 37

42Working procedures2.11 Vicinal diketones (diacetyl, 2,3-pentanedione)The metabolic processes of yeast produce 2-acetolactate and 2-acetohydroxibutyr

Page 38

43Working procedures5. Pipette 10 ml of the mixed distillate into each of two 50 ml Erlenmeyer flasks (main value solution, blank value solution).6. B

Page 39 - 2.10 Iso-α-acids and α-acids

44Working procedures2.11.1 Procedure for measuring vicinal diketones1. Prepare samples and blank value solution as described in the working procedure.

Page 40

45Working procedures2.12 Iron Iron in beer may originate from raw materials, filter aids, apparatus, pipes or cans, or beer foam stabilising agents. I

Page 41

46Working procedures4. Prepare a blank value solution in exactly the same way, but without adding the Ferrozin reagent. Prepare a blank value solution

Page 42

47Working procedures2.12.1.1 Executing the test with the sipper moduleInformation about the installation, module configurations and sample introductio

Page 44

49Section 3 Replacement Parts3.1 Replacement PartsDescription Catalog NumberMacro-cuvette (OG grade; path length = 20 mm) LZP331Cuvette set (path leng

Page 45 - 2.12 Iron

5Section 1 General Information1.1 Safety InformationBefore you install the software, you should read this manual thoroughly. Take note of all informat

Page 47

51Section 4 Contact InformationOrders/Repair servicePlease contact your representative:Information Required• Hach account number (if available)• Billi

Page 49 - Section 3 Replacement Parts

6General Information1.3 Important information about the manualCopyrightThe copyright to this User Manual remains with the manufacturer.The manual cont

Page 50

7General Information1.4 IntroductionThe LZV 570 Supplementary Software for Brewery Analysis is a collection of all spectrophotometric applications tha

Page 51 - Section 4 Contact Information

8General Information1.7 LiteratureMEBAK Brautechnische Analysenmethoden (Analysis methods for the brewing industry)Collected methods of the Mitteleuro

Page 52

9Section 2 Working procedures2.1 Bitter units (EBC method)PrincipleThe bitter substances, mainly iso-a-acids, are extracted from the acidified sample

Comments to this Manuals

No comments