Installation Page 10 Manual BÜHLER BU4010ff Characteristics: sampler 4010 The device consists of the following component parts: 1. Protecti

Page 3 - General Information

Installation Page 11 Manual BÜHLER BU4010ff Characteristics: sampler 4210 Compared to the standard samplers, the special sampler for sampling

Page 4

Operation Page 12 Manual BÜHLER BU4010ff Characteristics: sampler 4410 1. Protective top (can be opened) 2. Upper part of housing 3.

Page 5 - Redelivery for repair

Operation Page 13 Manual BÜHLER BU4010ff Characteristics: sampler 6010 1. Measuring unit with transducers and display 2. Control 3. Dosing

Page 6 - Precautionary labels

Operation Page 14 Manual BÜHLER BU4010ff Schematic illustration Water supply / water drain 1. Measuring transducer with display 2. Sampler

Page 7

Operation Page 15 Manual BÜHLER BU4010ff Characteristics: sampler 3010 1. Protective top (can be opened) 2. Upper part of housing 3. Ba

Page 8

Operation Page 16 Manual BÜHLER BU4010ff Dimensions of devices

Page 9

Operation Page 17 Manual BÜHLER BU4010ff

Page 10 - Installation

Operation Page 18 Manual BÜHLER BU4010ff Installing the apparatus - The workings described in this chapter of the manual must only be carried

Page 11

Operation Page 19 Manual BÜHLER BU4010ff Replacement of fuses 1. Main fuse of device (is installed on fold-out plate) Fine-wire fuse 230V/T8A

Page 12

Copyright by HACH LANGE GmbH © 1998 – 2012 Remarks HACH LANGE GmbH is not liable for possible faults in this documentation. Any liability for d

Page 13 - Operation

Operation Page 20 Manual BÜHLER BU4010ff Connections Terminal assignment – input signals Remark: Terminals K2 to K4 are optional depending on

Page 14 - Water supply / water drain

Operation Page 21 Manual BÜHLER BU4010ff The following sampling modes can be programmed: Sampling mode Description Example Time-proportiona

Page 15

Operation Page 22 Manual BÜHLER BU4010ff itself automatically proportionally to the flow. This is achieved by proportionally scaling the mA signa

Page 16 - Dimensions of devices

Operation Page 23 Manual BÜHLER BU4010ff Vacuum sampling system Metering vessel -structure- 1. Hose connector 2. Flange 3. Screw cap 4. E

Page 17

Operation Page 24 Manual BÜHLER BU4010ff Operation principle: 1. Inoperative position 2. Pinch-valve closes 3. Metering vessel is f

Page 18

Operation Page 25 Manual BÜHLER BU4010ff Troubleshooting – vacuum sampling system If a fault develops in your sampler, we can only provide prom

Page 19

Operation Page 26 Manual BÜHLER BU4010ff Flow-proportional sampling system The characteristic features of the flow-proportional sampling are: •

Page 20

Operation Page 27 Manual BÜHLER BU4010ff Function of the VAR Flow-proportional sampling system · Before the system can be used, it must be cali

Page 21

Operation Page 28 Manual BÜHLER BU4010ff Troubleshooting – flow-proportional sampling system If a fault develops in your sampler, we can only

Page 22

Operation Page 29 Manual BÜHLER BU4010ff Bypass metering vessel This sampling method is suitable for use in bypass systems with flow-rates from

Page 23 - Vacuum sampling system

General Information Page 3 Manual BÜHLER BU4010ff Table of contents Table of contents ...

Page 24

Operation Page 30 Manual BÜHLER BU4010ff REMARK: The pinch valve (9) is in inoperative position always closed and will be opened 1x per hour

Page 25

Operation Page 31 Manual BÜHLER BU4010ff Sample distribution at Bühler 4010/3010//6010 Ÿ Rotating distributor - Motor-driven rotating distri

Page 26

Operation Page 32 Manual BÜHLER BU4010ff Troubleshooting – distributor 4010/3010//6010 If a fault develops in your sampler, we can only provide

Page 27

Operation Page 33 Manual BÜHLER BU4010ff Sample distribution at Bühler 4410 – variants: 12 / 24 bottles Distributor The distributor system is a

Page 28

Operation Page 34 Manual BÜHLER BU4010ff Take out, empty or put in a bottle To empty a bottle, to take it out for cleaning or to put it in ag

Page 29 - Bypass sampling system

Operation Page 35 Manual BÜHLER BU4010ff 1. Distributor 2. Rinsing water connection 3. Container 4. Locking device for telescopic dra

Page 30

Operation Page 36 Manual BÜHLER BU4010ff Troubleshooting – distributor Bühler 4410 If a fault develops in your sampler, we can only provide pr

Page 31 - Ÿ Rotating distributor

Operation Page 37 Manual BÜHLER BU4010ff Programming The menu structure is similar to a directory tree and is split up in main menus and subme

Page 32

Operation Page 38 Manual BÜHLER BU4010ff Navigation The sampler can be operated by means of the control unit. With the ARROW KEYS, the ENTER KEY

Page 33

Operation Page 39 Manual BÜHLER BU4010ff Settings with selection menu The cursor is positioned on the current selection line (inversely) and c

Page 34

General Information Page 4 Manual BÜHLER BU4010ff General information We are glad that you have chosen this product. When developing this dev

Page 35

Operation Page 40 Manual BÜHLER BU4010ff MAIN MENU STRUCTURE The following list shows the main menu level with the menu points of the submenus:

Page 36

Operation Page 41 Manual BÜHLER BU4010ff SETTINGS DATE/TIME SYSTEM SETTINGS • LANGUAGE • DISTRIBUTOR • MAX. SUCTION TIME • PRE PURGE • P

Page 37

Operation Page 42 Manual BÜHLER BU4010ff Description of the menus DISPLAY DISPLAY EXPLANATION / FUNCTION PROGRAMS STATUS/STOP • INFO • P

Page 38

Operation Page 43 Manual BÜHLER BU4010ff DIAGNOSIS/TEST COMPONENT TEST • DIAPHRAGM PUMP • PINCH VALVE • VALVE SYSTEM • DISTRIBUTOR • DIGI

Page 39

Operation Page 44 Manual BÜHLER BU4010ff • PUMP POWER • ANALOGUE SIGNAL • DISPLAY • PAUSE DURATION • PROGR. INPUT • OUTPUT SIGNAL Th

Page 40

Operation Page 45 Manual BÜHLER BU4010ff Examples of programs Programming of a time-proportional sampling program Select PROGRAMS in the main m

Page 41

Operation Page 46 Manual BÜHLER BU4010ff Set the BOTTLE FILL TIME (here: each bottle is filled for 1 hour). Terminate programming.

Page 42 - Description of the menus

Operation Page 47 Manual BÜHLER BU4010ff - QT-AUTOMATIC (Selection is only available for Flow program) (Set of MIN. QT-TIME and/or

Page 43

Operation Page 48 Manual BÜHLER BU4010ff Program end After having defined the start conditions, the program end can be set as follows:

Page 44

Operation Page 49 Manual BÜHLER BU4010ff - INFO Display of information regarding the currently running program: current bottle, samples re

Page 45

General Information Page 5 Manual BÜHLER BU4010ff Redelivery for repair Before returning any appliances to us, please pay attention to the fol

Page 46

Operation Page 50 Manual BÜHLER BU4010ff Flow-proportional sample extraction According to the output signal of your flow meter either the opera

Page 47

Operation Page 51 Manual BÜHLER BU4010ff FREE PROGRAMMABLE INPUTS Ø PROGR. INPUT Ø ADDITIONAL INPUT 1 Ø ADDITIONAL INPUT 2 Ø ADDITIONA

Page 48

Operation Page 52 Manual BÜHLER BU4010ff OUTPUT SIGNALS As an option are 5 Output signals available, which are free configurable. OUTPUTSIGNAL

Page 49

Operation Page 53 Manual BÜHLER BU4010ff ERROR MESSAGES Error code Text / meaning 1 Error distributor 2 Error suction 4 Error electrodes 5 E

Page 50

Maintenance Page 54 Manual BÜHLER BU4010ff Maintenance The apparatus should be cleaned regularly in accordance with the degree of contamination

Page 51

Spare parts / accessories page 55 Manual BÜHLER BU4010ff Spare parts / accessories BÜHLER 3010, 4010, Version with 1 container (1x25 L) BM6004

Page 52

Spare parts / accessories page 56 Manual BÜHLER BU4010ff Article No. Designation 0040428 Bodenblech für 4x6 0040422 Winkelschiene Tragewanne 24x1

Page 53

Spare parts / accessories page 57 Manual BÜHLER BU4010ff BM30005 Metering vessel 500 ml (only possible at standard vacuum system) BM69401 O-rin

Page 54 - Maintenance

Spare parts / accessories page 58 Manual BÜHLER BU4010ff Spare parts of BÜHLER 4410 BM300016 1,6 L Duran50 glass bottle BM300028 2 L Duran50 gl

Page 55

Spare parts / accessories page 59 Manual BÜHLER BU4010ff Spare parts of BÜHLER 3010 BM900766 Hood complete BM40406 Cover of cooled compartm

Page 56 - Spare parts / accessories

General Information Page 6 Manual BÜHLER BU4010ff Safety information Please read this entire manual before unpacking, setting up or operating th

Page 57

Warranty and liability Page 116 Manual BÜHLER BU 4010ff Warranty and liability The manufacturer warrants that the product supplied is free of m

Page 58

Contact Page 61 Manual BÜHLER BU 4010ff Contact HACH LANGE GMBH Willstätterstraße 11 D-40549 Düsseldorf Tel. +49 (0)211 5288-0 Fax +49 (0)211 52

Page 59

Contact Page 62 Manual BÜHLER BU 4010ff Unit 1, Chestnut Road Western Industrial Estate IRL-Dublin 12 Tel. +353(0)1 4602522 Fax +353(0)1 450933

Page 60

Page 63 Manual BÜHLER BU 4010ff

Page 61 - Contact

Installation Page 7 Manual BÜHLER BU4010ff Device designation 4010 Housing Stainless steel with 40 mm insulation, (material 1.4301/ SS304) / PS

Page 62

Installation Page 8 Manual BÜHLER BU4010ff *) with opened top Weight 100 kg with composite container; higher weight when using several bottles a

Page 63

Installation Page 9 Manual BÜHLER BU4010ff for bottle variants: 2 x 10 L, 4 x 5 L, 12 x 1,6 L • 1400 (2175*) x 800 x 850 mm for bottle variants:

Comments to this Manuals

No comments