Hach-lange DRB 200 Thermostat User Manual

Browse online or download User Manual for Equipment Hach-lange DRB 200 Thermostat. Hach-Lange DRB 200 Thermostat User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 32
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
DOC022.53.00619
Digital Reactor Block 200
(DRB 200)
Instrument Manual
© Hach Company, 2003. All rights reserved. Printed in Germany. eac/dk 8/03 1ed
Page view 0
1 2 3 4 5 6 ... 31 32

Summary of Contents

Page 1 - Instrument Manual

DOC022.53.00619 Digital Reactor Block 200(DRB 200) Instrument Manual© Hach Company, 2003. All rights reserved. Printed in Germany. eac/dk 8/03 1ed

Page 2

10IntroductionThe actual temperatures of the heating blocks and the remaining time are visible in the display while temperature programs are active. F

Page 3 - Table of Contents

11IntroductionFigure 3 Menu StructureInitializingV 1.0COD TOCStart StartSelect blockleftrightSelect programCOD TOCCOD: 150°C 120’OKTOC: 105°C 120’OKSe

Page 5 - Safety Precautions

DANGERHandling chemical samples, standards, and reagents can be dangerous. Review the necessary Material Safety Data Sheets and become familiar with a

Page 7 - Specifications

15Section 2 Instrument Use2.1 Starting-upDANGER The ventilation slits in the lid must not be covered, or overheating may occur.1. Place the instrument

Page 8

16Instrument Use2. Press the right arrow key to scroll through the menu. Select the required language (see Tab l e 1). 3. The instrument is automatic

Page 9 - Section 1 Introduction

17Instrument Use5. Place the vials in the appropriate heating block and close the protective lid. 6. Start the program using the left key. 7. The time

Page 10 - Introduction

18Instrument UseTable 3 Stored Programs Program DescriptionCOD Program Heats vials for 2 hours at 150 °C. In the cooling phase, 4 beeps indicates that

Page 11

19Instrument Use2.5 Setting User ProgramsThe DRB 200 can accommodate three user programs in storage locations PRG1, PRG2, and PRG3. 1. Select PRG1 fro

Page 14

21Section 3 MaintenanceThere are no scheduled maintenance requirements for the instrument. To ensure reliable and precise operation, it must be kept c

Page 15 - Section 2 Instrument Use

22Maintenance1. Fill a clean, empty vial with glycerol at room temperature, and insert the thermometer until it touches the bottom of the vial. 2. Whe

Page 16 - Instrument Use

At Hach Company, customer service is an important part of every product we make.With that in mind, we have compiled the following information for your

Page 18

25Parts and AccessoriesDescription Part No.DRB200-1 with 9 holes for 16 mm vials and 2 holes for 20 mm vials ...

Page 19

26How To OrderInformation RequiredTechnical and Customer Service (U.S.A. only)Hach Technical and Customer Service Department personnel are eager to an

Page 20

27Repair ServiceAuthorization must be obtained from Hach Company before sending any items for repair. Please contact the HACH Service Center serving y

Page 21 - Section 3 Maintenance

28WarrantyHach Company warrants this product to the original purchaser against any defects that are due to faulty material or workmanship for a period

Page 22 - Maintenance

29CertificationHach Company certifies this instrument was tested thoroughly, inspected and found to meet its published specifications when it was ship

Page 23 - General Information

3Table of ContentsSafety Precautions...5Specifications ..

Page 24

30Certification, continuedtest records by REICHL (Report No. 030028) and certified compliance by Hach Company.Standards include:EN 61000-3-2 Harmonic

Page 25 - Parts and Accessories

31Certification, continuedcase the user will be required to correct the interference at his own expense. The following techniques of reducing the inte

Page 28

5Please read this entire manual before unpacking, setting up, or operating this instrument. Pay particular attention to all danger and caution stateme

Page 29 - Certification

6Safety PrecautionsSafety EquipmentUse protective clothing when operating the reactor, including goggles or face mask, and gloves. Reagent SpillsClean

Page 30 - Certification, continued

7SpecificationsSpecifications are subject to change without notice. Dimensions 250 x 145 x 310 mm (W x H x D)Weight LTV082.53.30001: 2 kg instrument,

Page 32

9Section 1 IntroductionThe DRB 200 is supplied as two models, with either one or two heating blocks (Figure 1). The heating blocks can heat solutions

Comments to this Manuals

No comments