DOC023.52.90171
TSS EX1 sc
User Manual
07/2013, Edition 5A
Turbidity and Solid matter sensor TSS EX1 sc
II 2G Ex d IIC T6 Gb Ta = –10 to 50 °C
II 2D Ex tb IIIC T 80 °C Db Ta = –10 to 50 °C
0820 IBExU09 ATEX 1156
© HACH-LANGE GmbH, 2009, 2011, 2012, 2013. All rights reserved. Printed in Germany
Page view 0
1 2 ... 36

Summary of Contents

Page 1 - TSS EX1 sc

DOC023.52.90171TSS EX1 sc User Manual07/2013, Edition 5ATurbidity and Solid matter sensor TSS EX1 sc II 2G Ex d IIC T6 Gb Ta = –10 to 50 °C II 2D Ex

Page 2

10General information

Page 3 - Table of contents

11Section 3InstallationNote: Depending on the area of application, the sensor may have to be installed with additional optional accessories 3.1 Instal

Page 4

12Installation3.2 Installation sensor pipe installation option Figure 4 Installation options3.3 Grounding3.4 Connect the sensor cable1. Unscrew the pr

Page 5 - Section 1 Specifications

13InstallationFigure 5 Connect the sensor plug to the sc controllerFigure 6 Pin assignment3.4.1 Cable extension with terminal box LZY586 Use for cable

Page 7 - 2.1 Safety information

151515Section 4 Operation4.1 sc controller operationThe sensor can be operated with all sc controllers. Become familiar with the functionality of the

Page 8 - 2.3 Measuring principle

16Operation16Operation16Operation4.4 Menu structureNote: Refer to Section 6 Malfunctions, causes, resolution for a list of all error and warning messa

Page 9 - 2.6 Function check

17Operation17Operation17OperationOUTPUT MODE Behavior of the outputs during calibration or while the zero point is being setHOLDACTIVETRANSFERSELECTIO

Page 10 - General information

18Operation18Operation18Operation4.5 CALIBRATENote: Turbidity measurement has been calibrated by the manufacturer — it does not need to be calibrated

Page 11 - Section 3Installation

19Operation19Operation19OperationAt least a 1-point calibration must be carried out for a solid matter measurement. In difficult application condition

Page 13 - Installation

20Operation20Operation20Operation4. Press CALIBRATE and confirm.5. Press CALIBRATE and confirm.6. Press RECORD and confirm.7. Press POINT... (point 1,

Page 14

21Operation21Operation21Operation4.5.2.3 1 to 3 point calibrationNote: It is imperative to calibrate for solid matter measurement (refer to section 4.

Page 15 - Section 4 Operation

22Operation22Operation22Operation5. Press CALIBRATE and confirm.A mark "<<" is displayed after the recorded point or points for approx

Page 16 - 4.4 Menu structure

23Section 5 MaintenanceThe cleanliness of the measurement windows in the sensor head is decisive for the accuracy of the measurement results!Check the

Page 17 - Operation

24Maintenance

Page 18 - 4.5 CALIBRATE

25Section 6 Malfunctions, causes, resolution6.1 Error messagesPossible sensor error messages are displayed by the sc controller.6.2 Warning messagesPo

Page 19

26Malfunctions, causes, resolution

Page 20

27Section 7 Replacement parts and accessories 7.1 Replacement partsDescription Catalog numberManual (xx = language code) DOC023.xx.901717.2 Accessor

Page 21

28Replacement parts and accessories

Page 22

29Section 8 Contact information HACH Company World HeadquartersP.O. Box 389 Loveland, Colorado 80539-0389 U.S.A. Tel (800) 227-HACH (800) -227-4224 (U

Page 23 - Section 5 Maintenance

3Table of contentsSection 1 Specifications ...

Page 24 - Maintenance

30Contact informationHACH LANGE D.O.O.Fajfarjeva 15 SI-1230 Domžale Tel. +386 (0)59 051 000 Fax +386 (0)59 051 010 [email protected] www.hach-lange.s

Page 25 - 6.2 Warning messages

31Section 9 Warranty and liabilityThe manufacturer warrants that the product supplied is free of material and manufacturing defects and undertakes the

Page 26

32Warranty and liability

Page 27 - 7.2 Accessories

33Appendix A Modbus register Table 3 Sensor modBUS registers Tag Name Group Name Register Data Type Length R/W DescriptionTURBIDITY FNU Measurement 4

Page 28

34Modbus registerFormatMinPR Configuration 40071 Float 2 R Solid Lower Limit in PercentFormatMaxPR Configuration 40073 Float 2 R Solid Upper Limit in

Page 29

35IndexAAreas of application ... 8CCable length ...

Page 31

4Table of contents5.2 Clean the measurement windows ...

Page 32 - Warranty and liability

5Section 1 SpecificationsSpecifications are subject to change without notice. MeasurementMeasurement methodCombined multiple-beam alternating light t

Page 33 - Appendix A Modbus register

6Specifications1.1 DimensionsFigure 1 DimensionsMiscellaneousInspection interval upon request 1/year service contract with warranty extension to 5 yea

Page 34 - Modbus register

7Section 2 General information2.1 Safety informationPlease read this entire manual before unpacking, setting up, or operating this equipment. Pay atte

Page 35

8General information2.1.2 Warning labelsRead all labels and tags attached to the instrument. Failure to do so may result in personal injury or damage

Page 36

9General informationUp to three calibration points can be defined for a strongly fluctuating medium. The combined multiple-beam alternating light tech